Industry Knowledge & Technical Reference

Petroleum Equipment & Compliance Glossary.

The definitive technical index of fuel storage terminology (UST vs. AST, UL 142 vs. UL 2085, Fireguard® vs. Flameshield®), automatic tank gauge monitoring, and environmental compliance frameworks across EPA, Georgia EPD, and Texas TCEQ.

Showing 22 of 22 terms
USTStorage Tanks & Piping

Underground Storage Tank

Authoritative Direct Definition

An underground storage tank (UST) is a tank and connected underground piping with at least 10 percent of its combined volume buried beneath the ground surface. USTs store petroleum fuels and hazardous substances under federal EPA 40 CFR Part 280, Georgia EPD, and Texas TCEQ Chapter 334 standards.

Referenced Standards & Codes:

EPA 40 CFR Part 280PEI RP100TCEQ 30 TAC 334
APEC Professional ImplementationExplore Tank Construction
ASTStorage Tanks & Piping

Aboveground Storage Tank

Authoritative Direct Definition

An aboveground storage tank (AST) is a stationary container situated above the soil grade used for bulk storage of motor fuels, aviation fuel, and industrial lubricants. AST installations must comply with EPA SPCC regulations under 40 CFR Part 112 and NFPA 30/30A flammable liquid fire codes.

Referenced Standards & Codes:

EPA 40 CFR Part 112NFPA 30NFPA 30A
APEC Professional ImplementationExplore Tank Construction
UL 142 vs. UL 2085Storage Tanks & Piping

UL 142 vs. UL 2085 Tank Standards

Authoritative Direct Definition

UL 142 designates the safety standard for steel aboveground tanks storing flammable liquids with standard atmospheric venting, whereas UL 2085 certifies protected aboveground tanks featuring a 2-hour furnace fire endurance rating, projectile resistance, and vehicle impact protection for reduced setback requirements.

Referenced Standards & Codes:

Underwriters Laboratories (UL)NFPA 30
APEC Professional ImplementationExplore Tank Construction
Fireguard® vs. Flameshield®Storage Tanks & Piping

Fireguard® vs. Flameshield® Tanks

Authoritative Direct Definition

Fireguard® is a thermally insulated, double-wall AST certified to UL 2085 with 2-hour fire endurance and ballistic impact resistance. Flameshield® is a UL 142 double-wall steel tank engineered with a 2-hour fire test certification for applications where ballistics protection is not mandated by the local AHJ.

Referenced Standards & Codes:

Steel Tank Institute (STI)UL 2085UL 142
APEC Professional ImplementationExplore Tank Construction
Secondary ContainmentStorage Tanks & Piping

Secondary Containment & Interstitial Monitoring

Authoritative Direct Definition

Secondary containment provides a liquid-tight outer barrier surrounding the primary tank or pressurized piping. Interstitial monitoring continuously inspects the annular space between walls using vacuum, hydrostatic fluid, or electronic liquid sensors to detect breaches before fuel escapes into the surrounding environment.

Referenced Standards & Codes:

EPA 40 CFR 280.20PEI RP1200
APEC Professional ImplementationExplore Tank Construction
Sumps (UDC & STP)Storage Tanks & Piping

Under-Dispenser Containment & Submersible Turbine Pump Sumps

Authoritative Direct Definition

Containment sumps are liquid-tight molded fiberglass or polyethylene enclosures placed beneath fuel dispensers (UDC) and above underground tank manways (STP). They prevent piping leaks, loose fittings, or dispenser drips from contaminating backfill soils and require periodic hydrostatic triennial tightness testing under PEI RP1200.

Referenced Standards & Codes:

PEI RP1200EPA 2015 UST Regulation
APEC Professional ImplementationExplore Tank Construction
EPA 40 CFR 280Environmental Regulations

EPA 40 CFR Part 280 Federal UST Regulations

Authoritative Direct Definition

EPA 40 CFR Part 280 establishes federal technical standards and corrective action requirements for all owners and operators of underground storage tank systems. Directives mandate secondary containment, monthly walk-through inspections, annual release detection testing, overfill prevention device verification, and financial responsibility demonstration.

Referenced Standards & Codes:

Environmental Protection Agency (EPA)
APEC Professional ImplementationView Compliance Solutions
TCEQ Chapter 334Environmental Regulations

TCEQ Title 30 TAC Chapter 334 Regulations

Authoritative Direct Definition

Texas Commission on Environmental Quality (TCEQ) Title 30 Texas Administrative Code (TAC) Chapter 334 governs the registration, design, construction, operation, release detection, and closure of underground and aboveground storage tanks in Texas, including mandatory Stage I vapor recovery certifications and licensed UST contractor oversight.

Referenced Standards & Codes:

State of Texas TCEQTAC Title 30 §334
APEC Professional ImplementationView Compliance Solutions
GA EPD Chapter 391-3-15Environmental Regulations

Georgia EPD Rules for Underground Storage Tanks

Authoritative Direct Definition

Georgia Department of Natural Resources Environmental Protection Division (EPD) Rules Chapter 391-3-15 regulates petroleum USTs across Georgia. Rules mandate Class A, B, and C certified operator training, triennial cathodic protection surveys, groundwater monitoring, and strict reporting protocols for suspected releases within 24 hours.

Referenced Standards & Codes:

Georgia EPDGa. Comp. R. & Regs. 391-3-15
APEC Professional ImplementationView Compliance Solutions
SPCC PlanEnvironmental Regulations

Spill Prevention, Control, and Countermeasure Plan

Authoritative Direct Definition

A Spill Prevention, Control, and Countermeasure (SPCC) plan is an EPA-mandated document (40 CFR Part 112) for facilities storing over 1,320 gallons of petroleum aboveground. The plan details physical containment structures, drainage controls, routine inspection logs, and emergency response procedures to prevent oil discharges into navigable waters.

Referenced Standards & Codes:

EPA 40 CFR Part 112Clean Water Act
APEC Professional ImplementationView Compliance Solutions
Stage I VREnvironmental Regulations

Stage I Vapor Recovery

Authoritative Direct Definition

Stage I vapor recovery captures hydrocarbon vapors displaced from underground fuel storage tanks when bulk fuel tanker delivery trucks unload gasoline. The displaced vapors are routed back into the tanker's vapor space through dedicated vapor-return hoses, preventing atmospheric VOC emissions.

Referenced Standards & Codes:

EPA Method 27CARB StandardsTCEQ Chapter 115
APEC Professional ImplementationView Compliance Solutions
Stage II VREnvironmental Regulations

Stage II Vapor Recovery & Decommissioning

Authoritative Direct Definition

Stage II vapor recovery captured fuel vapors during customer vehicle refueling through special vacuum-assist dispenser nozzles. As modern vehicles adopted Onboard Refueling Vapor Recovery (ORVR) canisters, EPA and state agencies authorized decommissioning of Stage II systems according to PEI RP500 guidelines.

Referenced Standards & Codes:

PEI RP500EPA ORVR RuleGeorgia EPD / TCEQ
APEC Professional ImplementationView Compliance Solutions
ATGMonitoring & Testing

Automatic Tank Gauge System

Authoritative Direct Definition

An Automatic Tank Gauge (ATG) is an electronic monitoring system (e.g., Veeder-Root TLS-450PLUS) connected to magnetostrictive in-tank probes. It continuously measures fuel level, gross volume, product temperature, water ingress, and performs automated static or continuous statistical leak detection (CSLD) to 0.2 GPH standards.

Referenced Standards & Codes:

EPA 40 CFR 280.43PEI RP1200NWGLDE Listed
APEC Professional ImplementationSchedule Sump & Tank Testing
LLD (MLLD & PLLD)Monitoring & Testing

Mechanical & Pressurized Line Leak Detectors

Authoritative Direct Definition

Line Leak Detectors protect pressurized underground product piping by sensing catastrophic breaches. Mechanical line leak detectors (MLLD) restrict fuel flow to 3 GPH if pressure drops below 10 PSI, while Electronic/Pressurized Line Leak Detectors (PLLD) utilize digital pressure transducers for automated hourly, monthly, and annual precision tests.

Referenced Standards & Codes:

EPA 40 CFR 280.44PEI RP1200
APEC Professional ImplementationSchedule Sump & Tank Testing
Hydrostatic TestingMonitoring & Testing

Hydrostatic Sump & Spill Bucket Testing

Authoritative Direct Definition

Hydrostatic testing is a liquid-integrity verification procedure where dispenser sumps, submersible turbine sumps, or spill buckets are filled with water to test for liquid tightness over a measured duration. Federal EPA mandates triennial testing to prevent sub-surface fuel contamination.

Referenced Standards & Codes:

PEI RP1200 Section 6EPA 2015 UST Rules
APEC Professional ImplementationSchedule Sump & Tank Testing
Cathodic ProtectionMonitoring & Testing

Cathodic Protection for Metallic Petroleum Equipment

Authoritative Direct Definition

Cathodic protection prevents electrochemical corrosion on buried steel tanks and metallic piping. Galvanic (sacrificial anode) systems use magnesium or zinc anodes to corrode in place of the steel, while impressed current systems apply an external direct electrical current. Systems require certified surveys every three years.

Referenced Standards & Codes:

NACE SP0285PEI RP100EPA 40 CFR 280.31
APEC Professional ImplementationSchedule Sump & Tank Testing
PEI RP100Electrical & Construction

PEI RP100 Petroleum Installation Standard

Authoritative Direct Definition

PEI RP100 is the Petroleum Equipment Institute's authoritative recommended practice for the installation of underground liquid storage systems. It governs tank excavation, geotextile fabrics, pea gravel bedding, tank anchoring, flex-connector installation, and precision pre-burial pneumatic testing.

Referenced Standards & Codes:

Petroleum Equipment Institute (PEI)
APEC Professional ImplementationView Electrical Services
PEI RP1200Monitoring & Testing

PEI RP1200 Testing of Petroleum Systems

Authoritative Direct Definition

PEI RP1200 outlines industry standard test procedures for spill buckets, containment sumps, overfill prevention devices, electronic leak detection sensors, and line leak detectors. It serves as the recognized testing code under EPA 2015 regulations and state compliance agencies.

Referenced Standards & Codes:

Petroleum Equipment Institute (PEI)EPA Recognized Code
APEC Professional ImplementationSchedule Sump & Tank Testing
NEC Class 1 Div 1Electrical & Construction

NEC Class 1, Division 1 & Division 2 Electrical Standards

Authoritative Direct Definition

National Electrical Code (NFPA 70 Article 500) Class 1 hazardous locations feature volatile flammable gases or vapors. Division 1 encompasses fuel dispenser interiors, dispenser sumps, and tanker vapor recovery zones where flammable atmospheres exist under normal operating conditions, requiring explosion-proof sealed conduit and intrinsically safe circuits.

Referenced Standards & Codes:

NFPA 70 (NEC)OSHA 1910 Subpart S
APEC Professional ImplementationView Electrical Services
E-Stop SystemElectrical & Construction

Emergency Fuel Shutoff (E-Stop) System

Authoritative Direct Definition

An Emergency Stop (E-Stop) system consists of high-visibility, labeled push-button switches installed both inside convenience stores and outdoors across fuel islands. When triggered, the system instantly de-energizes all submersible turbine pumps and dispenser electrical circuits per NFPA 30A requirements.

Referenced Standards & Codes:

NFPA 30A Chapter 6NEC Article 514
APEC Professional ImplementationView Electrical Services
Outdoor EMVElectrical & Construction

EMV Compliance for Automated Fuel Dispensers

Authoritative Direct Definition

Outdoor EMV (Europay, Mastercard, Visa) compliance requires fuel retailers to integrate encrypted chip-card readers and secure hybrid point-of-sale PIN pads directly into forecourt fuel dispensers, eliminating fraudulent magnetic stripe skimming liability and ensuring PCI-DSS network compliance.

Referenced Standards & Codes:

PCI-DSSEMVCo StandardsMajor Card Brand Mandates
APEC Professional ImplementationView Electrical Services
DEFStorage Tanks & Piping

Diesel Exhaust Fluid Storage & Dispensing

Authoritative Direct Definition

Diesel Exhaust Fluid (DEF) is a non-hazardous solution of 32.5% high-purity urea and deionized water used in selective catalytic reduction (SCR) systems. DEF freezes at 12°F (-11°C) and is corrosive to carbon steel, requiring heated enclosures, ISO 22241 compatible stainless steel or polyethylene tanks, and dedicated closed dispensing systems.

Referenced Standards & Codes:

ISO 22241PEI RP1100
APEC Professional ImplementationExplore Tank Construction
Start Your Project

Build Your
Gas Station
Business.

APEC handles every stage — design, construction, and long-term maintenance — so you can focus on running a profitable fueling operation.

35+

Years of Experience

100%

Licensed & Insured

Trusted by hundreds of operators across the country